Hotline (+84) 906922412
FD EI Fire Damper
  • FD EI Fire Damper
  • FD EI Fire Damper
  • FD EI Fire Damper

FD EI Fire Damper

Description:

Automatic fire damper – no power supply required

Fusible link melts at 74°C, instantly triggering damper closure

Effectively blocks fire and smoke from spreading through air ducts

Certified EI 30 – EI 120, compliant with QCVN 06 fire regulations

Strong spring-loaded closing mechanism, ensuring airtight sealing

Easy installation, compatible with both round and rectangular ducts

Suitable for projects requiring PCCC approval and inspection

More cost-effective than motorized fire dampers

Ideal for factories, shopping malls, and high-rise buildings

Parameter:

Product code GSC.FD-EI
Fusible Link Melting Temperature 74°C
Metal Plate Material Galvanized steel sheet
Test Standard BS EN 15882-2:2015 ; ISO 10294
Fire Resistance Rating EI 30 - EI 45 - EI 60 - EI 90
  • GSC Fusible Link Fire Damper for HVAC Systems

    The GSC FD Fire Damper is a basic and highly reliable passive fire protection device, designed to automatically prevent the spread of fire through HVAC ductwork. With a simple mechanical operating principle, it is an essential component in fire safety systems for buildings, factories, and commercial complexes.

    Common product name: GSC FD Fusible Link Fire Damper
    Typical model code: GSC.FD-EI


    Main Functions

    The primary role of the GSC FD Fire Damper is to automatically seal the air duct in the event of a fire, thereby:

    • Isolating the fire by preventing flame propagation through ventilation ducts

    • Blocking smoke and toxic gases, protecting evacuation routes and occupants

    • Maintaining fire-rated compartment integrity where ducts penetrate fire-rated walls or floors


    Operating Principle

    The GSC FD Fire Damper operates fully mechanically, without any external power supply:

    1. Under normal conditions, the damper blades are held open by a fusible link.

    2. During a fire, the temperature inside the duct rises.

    3. When the temperature reaches the melting point of the fusible link (typically 72°C – 74°C), the link melts and breaks.

    4. The spring-loaded mechanism is released, instantly closing the damper blades.

    5. The duct opening is sealed, effectively stopping the spread of fire.

    This purely mechanical principle ensures high reliability, even during power failure.


    Typical Applications

    The FD fire damper is widely used in:

    • Basement ventilation systems

    • Industrial factories and workshops

    • Shopping malls and commercial buildings

    • Technical rooms, storage areas, and high fire-risk zones

    • Projects requiring compliance with QCVN 06:2021/BXD

    Its main function is to contain fire and smoke, preserve evacuation paths, and extend safe evacuation time.


    Key Technical Features

    • Fail-safe mechanical operation
      Works based on physical heat response, unaffected by electrical or control system failure

    • Durable construction
      Damper casing and blades made of galvanized steel or stainless steel, offering high heat resistance

    • Fire resistance rating (EI)
      Certified in accordance with QCVN 06:2021/BXD, available in:
      EI 30 / EI 60 / EI 90 / EI 120
      (Integrity & insulation maintained for 30–120 minutes)

    • Cost-effective solution
      Lower initial investment and maintenance cost compared to motorized fire dampers (MFD)


    Fire Rating Selection Guide

    Duct Type Recommended Model Suitable EI Rating
    Small round duct (Ø200–300) GSC.FD-EI30 EI 30
    Medium rectangular duct (500×300) GSC.FD-EI60 EI 60
    Floor-to-floor duct penetration GSC.FD-EI90 / EI120 EI 90–120

     

    Selecting the correct damper model ensures effective fire protection and simplifies PCCC inspection and approval.


    Maintenance & Periodic Inspection

    Although the FD damper operates automatically, regular inspection is essential to ensure long-term reliability.

    Recommended Inspection Frequency

    • Every 3 months for high fire-risk facilities

    • Every 6 months for standard buildings (offices, residential)

    • After any ductwork modification or renovation

    Basic On-Site Inspection Procedure

    • Remove inspection access cover (if available)

    • Check that damper blades move freely and are not obstructed

    • Test fusible link (using approved test samples)

    • Clean dust and debris from blades and frame

    • Lightly lubricate blade shaft if necessary

    ⚠️ Important: Do not modify the fusible link or damper structure, as this may invalidate fire certification.


    When Replacement Is Required

    The FD fire damper must be replaced if:

    • The fusible link has melted after a fire event

    • Physical deformation due to impact or corrosion is observed

    • Damper blades do not close completely

    • Fire certification label or technical documentation is missing

    Correct replacement with a certified EI-rated damper is mandatory for PCCC re-approval.


    Summary

    The GSC FD Fire Damper is a safe, economical, and regulation-compliant fire protection solution for HVAC systems. With a simple fusible link mechanism, certified EI fire resistance, and proven reliability, it plays a critical role in fire compartmentation and life safety.

    Choosing a QCVN 06:2021/BXD certified FD fire damper and installing it correctly is one of the most effective ways to ensure successful PCCC acceptance and long-term fire safety performance.

Contact quotation